Applications
Code: AP003
Supplier: Fike
The purpose of this application guide is to provide an understanding of the possible hazards associated with Electronic Discharge Machining and protection solutions utilizing Fike Carbon Dioxide Extinguishing Systems..
Code: AP004
Supplier: Fike
The purpose of this application profile is to provide an understanding of the possible hazards associated with dust collection systems and protection strategies utilizing Fike Carbon Dioxide Extinguishing Systems.
Code: AP005
Supplier: Fike
This application profile will discuss the potential fire hazards associated with diesel engines and provide protection solutions utilizing the Fike Micromist Water Mist Extinguising System.
Code: AP006
Supplier: Fike
The purpose of this application profile is to provide an understanding of the possible hazards associated with subfloor areas and protection solutions utilizing Fike’s Carbon Dioxide Extinguishing Systems.
Code: Ap007
Supplier: Fike
The purpose of this application profile is to provide an understanding of the possible hazards associated with wave solder machines and protection strategies utilizing Fike Carbon Dioxide Extinguishing Systems.
Code: CO 001
Supplier: Fike
The purpose of this application profile is to provide an understanding of the different marine applications and how the Fike Marine Carbon Dioxide Systems are configured.
Code: DG 003
Supplier: Fike
This Design Guide provides a step by step design process of a Fike Carbon Dioxide Extinguishing System protecting an EDM application.
Code: DG 004
Supplier: Fike
This Design Guide provides a step by step design process of a Fike Carbon Dioxide Extinguishing System protecting a Baghouse type Dust Collection System.
Code: DG 006
Supplier: Fike
This Design Guide provides a step by step design process of a Fike Carbon Dioxide Extinguishing System protecting subfloor spaces.
Code: DG 007
Supplier: Fike
This Design Guide provides a step by step design process of a Fike Carbon Dioxide Extinguishing System. There are numerous styles and types of Wave Solder Machines ranging from low to high capacity manufacturing.
|
Datasheets
Code: E.1.01.01
Supplier: Fike
CO2 cylinders are factory filled to capacity; partial fills are not allowed. The cylinders may be utilized in single or multiple cylinder applications as needed.
Code: E.1.02.01
Supplier: Fike
Fike Carbon Dioxide cylinders are equipped with a cylinder valve assembly to hold the CO2 agent in the cylinder until actuated. All Fike Carbon Dioxide cylinders are shipped from the factory as “Slave Cylinders” (Refer to Slave Valve sketch for details).
Code: E.1.03.01
Supplier: Fike
The Flexible Discharge Bend is used to provide a flexible connection between the CO2 cylinder valve and the discharge piping or the distribution manifold. The discharge bend has an internal check valve that prevents loss of agent should the system discharge while a cylinder is removed.
Code: E.1.04.01
Supplier: Fike
The Fike Carbon Dioxide Master Cylinder Valve can be actuated by two methods of opertion: Manual / Mechanical actuator or Electric solenoid actuator (12V or 24V DC)
Code: E.1.05.01
Supplier: Fike
The “S” Nozzle is primarily used for local application systems but is also listed and approved for use in total flooding applications.The “S” Nozzle Flange Kit is used to mount an “S” nozzle to the mounting surfaces of enclosures, hoods, ductwork, etc.
Code: E.1.06.01
Supplier: Fike
The Vent Nozzle is used for total flooding systems protecting ductwork, electrical compartments, collecting bins, or any other application that requires direct mounting of the nozzle.
Code: E.1.07.01
Supplier: Fike
The Baffle Nozzle is used for total flooding applications only. The nozzle should be located around the perimeter of the protected space. Each nozzle provides a 180o discharge pattern within the protected space. The Radial Nozzle is used for total flooding applications. The nozzle(s) can be located around the perimeter or in the center of the protected space.
Code: E.1.08.01
Supplier: Fike
The header safety relief is a device used to relieve a high pressure build up in a closed section of piping. The header vent plug is used to release a low pressure build-up that may occur in a closed piping system using time delays, selector valves or maintenance/stop valves.
Code: E.1.09.01
Supplier: Fike
Fike stop/maintenance valves are available in sizes ranging from 1/2" (15 mm) to 1 1/2" (40 mm). Stop valves are used for maintenance lock-out purposes to prevent the discharge of CO2 from the nozzles while the system is being worked on.
Code: E.1.10.01
Supplier: Fike
The Pressure Trip is used to release spring or weight activated devices to close doors and windows, open fuel dump valves, close fire dampers or close fuel supply valves. The pressure trip can be operated manually, by use of the pull ring; or pneumatically by the agent discharge pressure.
Code: E.1.11.01
Supplier: Fike
The C70-202 Pressure Switch is used to provide an electrical tie-in to the control panel that indicates the CO2 system has been activated. The pressure switch is also used to open, or close, electrical circuits for various functions such as equipment shutdown and alarm activation.
Code: E.1.12.01
Supplier: Fike
The C02-1231, Explosion-Proof Pressure Switch is commonly used to provide an electrical tie-in to the control panel that indicates the CO2 system has been activated mechanically. The pressure switch can also be used to open or close electrical circuits for various functions, such as equipment shutdown and alarm activation, upon system discharge. The pressure switch is designed for use in hazardous rated environments.
Code: E.1.13.03
Supplier: Fike
Instructional signs are provided to inform personnel of any potential hazards they face when operating certain devices or working within areas protected by CO2 systems.
Code: E.1.14.01
Supplier: Fike
The weigh beam assembly is a service tool that enables the system technician to determine the weight of agent in a C02 cylinder. The weigh beam is a one piece assembly that includes a lifting yoke, weigh beam and easy-to-read scale.
Code: E.1.15.0
Supplier: Fike
The Thermotec explosion-proof thermal detectors are used to detect the presence of heat beyond the detector’s temperature set-point for the purpose of activating a fire alarm and/or automatic suppression system.
Code: E.1.16.01
Supplier: Fike
Check valves are used to isolate the Main/Reserve system supplies. Check valves are available in sizes ranging from 1/2" to 2" (15-50mm) NPT. The body style has a female connection on both ends. The body is brass and the valve seat material is Buna-n.
Code: E.1.17.01
Supplier: Fike
Cylinder straps are used to secure the cylinder in place, on a single cylinder system, in accordance with OSHA and NFPA 12 requirements. The straps may be secured to any structurally solid surface.
Code: E.1.18.01
Supplier: Fike
Selector Valves are used to direct the flow of carbon dioxide into one specific hazard of a multiple hazard system. All selector valves are equipped with an electric solenoid actuator.
Code: E.1.19.01
Supplier: Fike
Cylinder Rack Assemblies are designed to rigidly support CO2 cylinders on multiple or main/reserve cylinder applications. Various configurations allow any combination of cylinders to be housed in a single row rack arrangement.
Code: E.1.20.01
Supplier: Fike
Cylinder Rack Assemblies are designed to rigidly support CO2 cylinders on multiple or main/reserve cylinder applications. Various configurations allow any combination of cylinders to be housed in a double row rack arrangement.
Code: E.1.21.01
Supplier: Fike
Cylinder Rack Assemblies are designed to rigidly support CO2 cylinders on multiple or main/reserve cylinder applications. Various configurations allow any combination of cylinders to be housed in a double row rack arrangement.
Code: E.1.22.01
Supplier: Fike
The Fike Marine Carbon Dioxide Extinguishing System is designed to be used on offshore applications where single or two-step manual actuation is required. The Fike Marine CO2 system utilizes superior engineered products to accomplish system operation utilizing fewer components which lowers cost and increases system reliability.
Code: E.1.23.01
Supplier: Fike
The Corner Pully system is required on a carbon dioxide system whenever remote pull box cable requires a change in direction. Corner Pulleys are installed as part of the cable houseing and provides a 90 degree direction change with minimal loss of force and elimination of induced cable kinking.
Code: E.1.24.01
Supplier: Fike
The Latch Door Pull Box on a carbon dioxide system is used to provide mechanical operation of the Stop / Selector Valve and/or the Local Lever Actuator from a remote location
Code: E.1.26.01
Supplier: Fike
Instructional signs are provided to inform personnel of any potential hazards they face when operating certain devices or working within areas protected by CO2 systems. All signs are made of stainless steel and have black lettering.
Code: E.1.27.01
Supplier: Fike
Selector Valves are used to direct the flow of carbon dioxide into one specific hazard of a multiple hazard system. All selector valves are equipped with an electric solenoid actuator.
Code: Material Safety Data Sheet
Supplier: Airgas
Contains Product Identification, Composition and information on ingredients, hazard identification, first aid, firefighting and accidental release measures, handling and sotrage. Also exposure controls, personal protection, physical and chemical properties, stability and reactivity, toxicological and ecological information, disposal considerations, and transportation and regulatory information.
|