Brochures
Fike’s Marine HFC-227ea system utilizes the same high performance valve technology as our commercial HFC-227ea system. This allows for more flexibility when placing cylinders around the hazard. HFC-227ea is an effective fire suppression agent applicable to a wide range of fire hazards. It quickly suppresses fires, and is recognized by the U.S. EPA as a non-ozone-depleting agent that is safe for installation in occupied spaces.
The Best Fire Suppression System on the market. HFC-227ea extinguishes a fire quickly by discharging in 10 seconds – or less! The system removes heat and breaks up the fire at the molecular level. HFC-227ea discharges as gas, leaves no residue and doesn’t require costly clean-up, unlike sprinklers and other systems.
The FIRERASER fire suppression system from Fike provides economical, on-board fire suppression for everything from computer cabinets to CNC machines, medical imaging equipment, electrical closets and even small data centers. Whether you’re a small business that depends on a small server rack or a big business that wants to protect critical equipment at the source, the FIRERASER fire protection system is the answer.
|
Applications
Code: AP 008
Supplier: Fike
To reduce the risks of personal injury, costly downtime and substantial equipment damage, an automatic fire suppression system is needed. More importantly, the system must be capable of rapidly detecting and extinguishing a fire without leaving damaging residue or creating a life safety hazard.
Code: AP 009
Supplier: Fike
Flammable liquid storage facilities are in many industrial and chemical plants as well as production facilities that use flammable liquids in various processes. These facilities store the flammable liquids used in processes such as painting, lubrication, fuel, and oil in areas called “Flammable Liquid Storage Areas”.
Code: DG 008
Supplier: Fike
This document is intended to provide useful information regarding the design of HFC 227ea systems. This information regards critical design decisions and provides insight to what options are available for specific challenges.
Code: FM 001
Supplier: Fike
Fike Marine HFC-227ea Systems are used for suppressing fires in specific hazards or equipment and in occupancies where an electrically nonconductive agent is essential or desirable, or where cleanup of other media presents a problem.
|
Datasheets
Code: C.1.01.01
Supplier: Fike
Fike Series 70 Clean Agent Containers are used in fire extinguishing systems to store the Clean Agent until a fire develops and the agent must be released. The Clean Agent is retained in the container by a valve assembly which contains a fast acting rupture disc.
Code: C.1.02.01
Supplier: Fike
The function of the Fike Nozzle, in a fire extinguishing system, is to distribute the Clean Agent in a uniform, predetermined pattern and concentration. The nozzles are designed to complete the discharge of Clean Agent in 10 seconds, or less, when installed within the design limitations of the Fike Design Manual.
Code: C.1.03.01
Supplier: Fike
Includes Reload Kits, Pressure Switch, Check Valves, and Victaulic Nipple and Coupling.
Code: C.1.04.01
Supplier: Fike
The Agent Release Module (ARM III), in conjunction with a Fike Control Panel, allows the electrical actuators used with Fike Clean Agent containers to be wired in “parallel”. This configuration substantially increases the overall reliability of the Clean Agent releasing circuit.
Code: C.1.05.01
Supplier: Fike
The Fike 70-1353 series Liquid Level Indicator is a simple manually operated device which provides a means to determine the Clean Agent liquid level in vertically mounted agent storage containers. Once the liquid level is determined, it can then be converted into pounds (kilograms) of Clean Agent present in the agent storage container.
Code: C.1.06.01
Supplier: Fike
The Interface Firing Module (IFM), Fike P/N 10-2136, is designed to allow an existing control panel (approved for releasing service) to connect with a Fike Clean Agent system.
Code: C.1.07.01
Supplier: Fike
HFC-227ea fire suppression agent is the first environmentally acceptable replacement for Halon 1301. HFC-227ea has a zero ozone depleting potential, a low global warming potential, and a short atmospheric lifetime.
Code: C.1.08.01
Supplier: Fike
The function of the Fike Engineered Discharge Nozzle, in a fire extinguishing system, is to distribute the Clean Agent in a uniform, predetermined pattern and concentration.
Code: C.1.09.01
Supplier: Fike
The MA (Manual Actuator) P/N 10-2225 provides an independent means of operating Fike clean agent systems which use the Gas Cartridge Actuator (GCA). It is designed to allow activation of GCAs in stand alone mode or supplementary to a normal releasing system in the event of a total power loss.
Code: C.1.10.01
Supplier: Fike
Instructional signs must be supplied in order to provide a system in which the function of all devices is easy to understand. Fike offers several different “Standard” signs to comply with NFPA and other industry requirements. Custom signs are available upon special request.
Code: C.1.11.01
Supplier: Fike
Fike Series S70 Clean Agent Containers are used in HFC-227ea fire extinguishing systems to store the Clean Agent until a fire develops and the HFC-227ea agent must be released.
Code: C.1.12.02
Supplier: Fike
HFC-125 fire suppression agent is an environmentally acceptable replacement for Halon 1301. HFC-125 has a zero ozone depleting potential, a low global warming potential, and a short atmospheric lifetime.
Code: C.1.20.01
Supplier: Fike
The Master Actuation Package is used to operate the solenoid operated HFC-227ea containers. The actuation package utilizes a 24 VDC electric solenoid and is connected to a small cylinder filled with nitrogen.
Code: C.1.21.01
Supplier: Fike
The Slave Actuation Package consists of three core components; a pneumatic valve assembly, nitrogen cylinder, and mounting bracket assembly.
Code: C.1.22.01
Supplier: Fike
The function of the Fike Engineered Discharge Nozzle, in a fire extinguishing system, is to distribute the Clean Agent in a uniform, predetermined pattern and concentration.
Code: C.1.23.01
Supplier: Fike
The Fike 70-1353 series Liquid Level Indicator is a simple manually operated device which provides a means to determine the Clean Agent liquid level in vertically mounted agent storage containers. Once the liquid level is determined, it can then be converted into kilograms of Clean Agent present in the agent storage container.
Code: C.1.24.01
Supplier: Fike
HFC-227ea fire suppression agent is the first environmentally acceptable replacement for Halon 1301. HFC-227ea has a zero ozone depleting potential, a low global warming potential, and a short atmospheric lifetime.
Code: C.1.25.01
Supplier: Fike
Accessories includes Reload Kits, Victualic Nipple, Victualic Coupling, Pressure Switch and Check Valves.
Code: C.1.26.01
Supplier: Fike
The Gas Cartridge Actuator (G.C.A.), P/N 70-1651, provides the necessary pressure to fully open all Fike’s Clean Agent containers utilizing a Fike fast acting rupture disc assembly.
Code: C.1.38.01
Supplier: Fike
Selector valves allow a single agent supply to be utilized for protection of multiple hazards, reducing the total amount of agent required.
Code: C.1.39.01
Supplier: Fike
The Solenoid Actuator Kit is used to operate / open the clean agent or carbon dioxide selector valve. The actuation package utilizes a 24 VDC electric solenoid with manual actuator button that is connected to a small cylinder filled with nitrogen.
Code: d1027
Supplier: Fike
The Agent Release Module (ARM III), in conjunction with a Fike Control Panel, allows the electrical actuators used with Fike Clean Agent containers to be wired in “parallel”. This configuration substantially increases the overall reliability of the Clean Agent releasing circuit.
Code: FE227
Contains Product Identification, Composition and information on ingredients, hazard identification, first aid, firefighting and accidental release measures, handling and sotrage. Also exposure controls, personal protection, physical and chemical properties, stability and reactivity, toxicological and ecological information, disposal considerations, and transportation and regulatory information.
Code: GCA
Supplier: Fike
Hazardous Chemical Material Safety Data Sheet, includes product identity, hazardous ingrediants and exposure limits, spill and leak procedures and health hazard data.
Code: M.1.01.01
Supplier: Fike
HFC-125 is a clean agent extinguishant used in Fike’s Fireraser system. HFC-125 has a zero ozone depleting potential, a low global warming potential, and a short atmospheric lifetime.
Code: M.1.02.01
Supplier: Fike
HFC-227ea is a clean agent extinguishant used in Fike’s Fireraser system. HFC-227ea is ideal for applications where clean-up of other media presents a problem, where weight versus suppression potential is a factor, where an electrically non-conductive medium is needed and where people compatibility is an overriding factor.
Code: M.1.03.01
Supplier: Fike
Fike's Fireraser clean agent storage containers store the extinguishing agent (either HFC-125 or HFC-227ea) until a fire develops and the agent is released. Containers are available in sizes of: 5, 10, 20, and 35 pounds (volumes of 2, 4, 8, and 15 liters).
Code: M.1.04.01
Supplier: Fike
All Fireraser clean agent containers come equipped with a balanced pressure valve that can be operated pneumatically, manually or electrically. The valve retains the agent in the container under pressure until it is released to put out a fire. The valve is suitable for use with either HFC-125 or HFC-227ea and is used on the full range of Fireraser containers from the 5-pound (2-liter) container to the 35-pound (15-liter) container.
Code: M.1.05.01
Supplier: Fike
The Fireraser Automatic Actuation Kit (P/N 70-209 used with HFC-125 systems, and P/N 70-208 used with HFC-227ea systems) provides a means for automatically detecting a fire and releasing the extinguishant. This type of actuation is used in situations where a person might not always be present to manually actuate the system in the event of a fire.
Code: M.1.06.01
Supplier: Fike
The Fireraser Remote Manual Actuation Kit (P/N 70-203 ) provides a means for manually actuating the Fireraser system without having to be near the clean agent container to do so. This type of actuation is used when automatic actuation is not desired, and allows the actuator to be placed in a convenient, readily accessible location.
Code: M.1.07.01
Supplier: Fike
Discharge nozzles are design to distribute Fireraser extinguishing agent (either HFC-125 or HFC-227ea) throughout the protected space. Nozzles are available in two styles, either "in-cabinet" or "pendant".
Code: M.1.08.01
Supplier: Fike
Accessories includes manual pull release kit, manual push release, and system abort switch.
|